The machine directly powers off and restarts when the initialization function is triggered in any method
The cause of this fault is a short circuit, short circuit is easy to damage the mainboard and platform adapter board.
Following troubleshoot method for your reference.
1. 20P colour cable short circuit; Platform FFC short circuit; LED display board broken; LED light short circuit
- Turn off the power and replace the 20P color cable
- Turn off the power, replace the LED display board sets
- Replace the LED light cable
2. Short circuit of aluminum substrate
- Turn off the power, and replace the aluminum substrate assembly
3. Nozzle adapter board short circuit; Nozzle CFC cable adapter board; Nozzle FFC cable is damaged or contact is poor
- Turn off the power and replace the nozzle adapter board
- Turn off the power and replace the PCB-FFC adapter board
- Turn off the power and check if the FFC cable of the nozzle has defects such as false connection, crushing, and plug loose. If yes, replace it.
4. Short circuit of internal components of the nozzle
- Turn off the power and replace the nozzle assembly
5. Mainboard damaged
- Turn off the power and replace the mainboard
6. CPU damaged
- Turn off the power and replace the CPU
Comments
0 comments
Please sign in to leave a comment.